StartPrepare a sampleQueuesExperimentsDataContact Get certified

Instrument online, queue running

The 400 MHz NMR facility at BCE

Get certified in half an hour, place your tube in the changer, and your data arrives by email two minutes after the run ends.

¹H spectrum of ethyl acetate, 400 MHz Hover or tap a peak. Splitting is drawn wider than real so you can see it.
9.4 TSuperconducting magnet
400 MHzProton frequency
BB/H/DSmartProbe, auto tune and match
24Changer positions, one reserved
24 hAutomated queue, every day

How it works

Three steps to your first spectrum

This is the whole workflow, from first visit to the data on your laptop. Each step takes less time than finding a parking spot at Gustav Wieds Vej.

  1. Complete the induction course

    Five short modules and a ten-question test, once, online. Pass at 90% and your TopSpin username is created within two working days.

    Start the course
  2. Prepare and submit your sample

    A 178 × 5 mm tube, 600 µL of deuterated solvent, no particles, a clear label. Pick the day or night queue and place it in the changer.

    Prep rules and queues
  3. Collect your data

    An email from data@bcenmr.dk arrives within two minutes of completion, with a Proton Drive backup. Process in MestreNova or TopSpin.

    Data and software

The instrument

What you are working with

A research-grade Bruker Ascend Evo with a 9.4 tesla superconducting magnet and a SmartProbe that detects ¹H, ¹³C, ¹⁵N, ¹⁹F and ³¹P without a probe change. The 24-position SampleXpress changer loads, shims and ejects on its own, so experiments run unattended through the night and over the weekend.

Full specifications
Magnet
9.4 T superconducting, actively shielded, cryo-cooled with near-zero drift
Frequency
400 MHz for ¹H
Probe
SmartProbe BB/H/D with automatic tuning and matching
Changer
SampleXpress with 24 positions, automatic load, eject and shim
Nuclei
¹H, ¹³C, ¹⁵N, ¹⁹F, ³¹P and other common NMR-active nuclei
Operation
Automated queue around the clock, unattended nights and weekends
Data
Emailed within two minutes of completion, backed up to Proton Drive

Prepare a sample

Five rules. No exceptions.

Every failed experiment traces back to one of these five steps. Tick them off before you walk to the lab.

600 µL ≈ 4 cm 178 mm 5 mm
The 600 µL column fills the active region of the probe coil. Less loses sensitivity; more makes shimming difficult.

Pre-flight checklist

0 of 5 checked
Ready to submit. Pick the day or night queue below.

Queues

Day queue or night queue

Decide before you walk to the lab. Short runs go in the day queue, long runs in the night queue.

A 24-hour day at the changer

Night samples go in after 15:00
Day queue
08:00 – 18:00

For experiments under 35 minutes. First come, first served. Place your sample during working hours and it runs in order.

Position 24 holds the weekly calibration reference. Never use it, under any circumstances.
Night queue
18:00 – 08:00

For experiments of 35 minutes or longer, and for weekends. Place samples after 15:00 only, so the changer stays free for day users.

Collect within 48 hours of the run. The confirmation email tells you when it finished.
How long experiments take
ExperimentScansTimeQueue

Experiments

Find the right experiment

Pick the question you are asking. Only the matching experiments appear.

Pick a question above, or search, to see which experiments fit.

No experiment matches thatClear the search or pick a question. Not sure what you need? Write to axelro@bce.au.dk.

Solvents

Choosing a solvent

Pick a solvent to see the residual shifts to reference against and what it suits.

Pick a solvent above.

Compare all solvents in a table
SolventType¹H, ppm¹³C, ppmGood for

Get certified before you touch the instrument

Five modules, a sample-preparation simulation and a ten-question test. Pass at 90% for an instant certificate, with unlimited retries. About 35 minutes.

Start the course

Your data

Delivered automatically

When the run ends, the data comes to you. Add data@bcenmr.dk to your safe senders so it never lands in spam.

  1. The run finishesIn the automated queue
  2. An email arrivesFrom data@bcenmr.dk, within two minutes
  3. You downloadDirect link to the Bruker folder
  4. You keep a copyThe backup is kept for a limited time only

MestreNova

Recommended for beginners. Download from mestrelab.com; the AU licence is on the iNANO website and needs the AU network or VPN.

TopSpin

Bruker's own software, free academic licence at bruker.com. Best for advanced processing and for looking at the raw FID.

Resources

Reference tables and tutorials

The few pages worth bookmarking.

Watch before your first run, three short videos
Sample preparationBefore you load a tube
MestreNova walkthroughProcessing data for the first time
How NMR worksA conceptual explainer

FAQ

Questions every new user asks

Not here? Write to axelro@bce.au.dk before you get stuck.

Which software should I use?

MestreNova if you are new: download from mestrelab.com, licence from the iNANO website on the AU network or VPN. TopSpin if you want the raw FID and advanced processing: free academic licence at bruker.com. Both open Bruker data directly.

Can I book the instrument for a specific time?

No. The queue is first come, first served and runs automatically. For unusual experiments or very long runs, contact Axel first.

Why does ¹³C need so much more sample than ¹H?

¹³C is 1% abundant; ¹H is 99.9%. Far fewer nuclei are visible per milligram. Signal-to-noise grows with the square root of the scan count, so doubling it needs four times the scans. More sample is nearly always the better fix.

My spectrum has broad peaks and a poor baseline. Why?

Almost always one of four things: particles in the tube, the wrong tube size, too little liquid, or a protonated solvent. Run through the five rules and resubmit.

Do I need a TopSpin username?

Yes, for every experiment in the automated queue. Axel creates it after you pass the induction course; the certificate email notifies him automatically.

Contact

Who to ask

Sample preparation, experiment choice, software or access. Ask before you get stuck; it saves everyone's instrument time.

Axel Rosenvinge
Axel RosenvingeNMR Lab Manager, BCEaxelro@bce.au.dk
Daniel Rasmussen
Daniel RasmussenSuperuser, BCEdr@bce.au.dk

Where

Department of Biological and Chemical Engineering, Aarhus University, Gustav Wieds Vej 10, 8000 Aarhus C

When

The queue runs around the clock. For in-person access or hands-on training, write to Axel to arrange a time.

↑ ↓ to moveEnter to openEsc to close